Click to Enlarge

Circa 2017 Horizon BQ-470 & Horizon HT30C Trimmer

ALI Reference #: 105276
 

Circa 2017 Horizon BQ-470 & Horizon HT30C Trimmer

Great pairing to add to any print shop to incoroporate a Binding unit and a trimmer. This can help to increase productivity and profits as well as services that can be offered to new and existing customers.
Horizon Details:

HTC30 Trimmer

  • Untrimmed Book Size Max 320 x 235 mm, Min 204 x 136 mm
  • Trimmed Book Size Max 305 x 230 mm, Min 148 x 105 mm
  • Trim Width .08″ to 3.93″
  • Trim Height 2.0″
  • Book Pile Height 11.8″
  • Production Speed 440 books/hour (book thickness 25mm, 2 piled books); 500 books/hour (book thickness 10mm, 5 piled books)
  • Voltage/Frequency 3-Phase 200 to 220 V, 50/60 Hz
  • Machine Dimensions 92.6″ (W) x 45.7″ (D) x 54″ (H)

BQ470
  • Binding Mode Binding with milling, Binding without milling and Padding
  • Number of Clamps 4
  • Book Block Size
  • (Top-Bottom x Fore-edge) Max. 320 x 320 mm (12.59” x 12.59”)
  • Min. 145 x 105 mm (5.71” x 4.14”)
  • Book Thickness 1 to 65 mm (0.040” to 2.560”)
  • The book thickness can be limited depending on the sheet weight, book size and milling depth.
  • Cover Size
  • (Top-Bottom x Fore-edge) Max. 320 x 660 mm (12.59” x 25.98”)
  • Up to 350 mm or 13.77” forwards from the clamp face.
  • Up to 310 mm or 12.20” backwards from the clamp face.
  • Min. 135 x 225 mm (5.32” x 8.86”)
  • Up to 115 mm or 4.53” forwards from the clamp face.
  • Up to 110 mm or 4.34” backwards from the clamp face.
  • Cover Weight Range Normal Paper 81.4 to 302.4 gsm
  • Coated Paper 104.7 to 348.9 gsm
  • Cover Pile Height Max. 150 mm (5.9”)
  • Warm Up Time 60 min.
  • Glue Temperature Spine Glue Tank EVA: 150 to 210 degrees Celsius (180 degrees Celsius for HM-220)
  • PUR: 110 to 140 degrees Celsius
  • Side Glue Tank EVA: 150 to 210 degrees Celsius (170 degrees Celsius for HM-403)
  • Max. Milling Depth 4 mm (0.157")
  • Cycle Speed Max. 1,350 cycles/hr. (EVA)
  • Max. 1,000 cycles/hr. (PUR)
  • Voltage Frequency 3-Phase 200 / 220 / 400 V, 50 / 60 Hz
  • The external transformer is necessary for 220 V / 400 V.
  • Heat Ouptut 13,030 kJ (3,120 kcal)
  • Rated Current 3-Phase 200 V 50 / 60 Hz 10.5 / 12.0 A (Max. 17.9 / 18.2 A)
  • 3-Phase 220 V 50 / 60 Hz 8.1 / 8.7 A (Max. 11.9 / 11.0 A)
  • 3-Phase 400 V 50 / 60 Hz 5.7 / 6.5 A (Max. 7.7 / 7.8 A)
  • Power Consumption 3-Phase 200 V 50 / 60 Hz 3.3 / 4.0 kW
  • 3-Phase 220 V 50 / 60 Hz 2.7 / 3.0 kW
  • 3-Phase 400 V 50 / 60 Hz 3.8 / 4.2 kW
Celebrating 40 years